https://reference.opcfoundation.org/v105/Core/docs/Part8/5.3.2/#5.3.2.2 More...

Inherits UnifiedAutomation.UaServer.DataItemModel.

Inherited by UnifiedAutomation.UaServer.AnalogItemModel, UnifiedAutomation.UaServer.AnalogUnitModel, and UnifiedAutomation.UaServer.BaseAnalogModel< T >.

Public Member Functions

 BaseAnalogModel ()
 Initializes a new instance of the BaseAnalogModel class. More...
 
 BaseAnalogModel (BaseAnalogModel template)
 Initializes a new instance of the BaseAnalogModel class. More...
 
- Public Member Functions inherited from UnifiedAutomation.UaServer.DataItemModel
 DataItemModel ()
 Initializes a new instance of the DataItemModel class. More...
 
 DataItemModel (DataItemModel template)
 Initializes a new instance of the DataItemModel class. More...
 
- Public Member Functions inherited from UnifiedAutomation.UaServer.BaseDataVariableModel
 BaseDataVariableModel ()
 Initializes a new instance of the BaseDataVariableModel class. More...
 
 BaseDataVariableModel (BaseDataVariableModel template)
 Initializes a new instance of the BaseDataVariableModel class. More...
 
- Public Member Functions inherited from UnifiedAutomation.UaServer.BaseVariableModel
 BaseVariableModel ()
 Initializes a new instance of the BaseVariableModel class. More...
 
 BaseVariableModel (BaseVariableModel template)
 Initializes a new instance of the BaseVariableModel class. More...
 
- Public Member Functions inherited from UnifiedAutomation.UaServer.ModelControllerBase
virtual ModelHandle GetModelHandle (StringTable namespaceUris, object instance)
 Gets the metadata handle. More...
 
virtual DataValue GetValue (IMapperContext context, ModelMapping mapping)
 Gets the value associated with the mapping. More...
 
virtual bool SetValue (IMapperContext context, ModelMapping mapping, DataValue value)
 Sets the value associated with the mapping. More...
 

Properties

EUInformation EngineeringUnits [get, set]
 Specifies the units for the AnalogItem value (e.g., DEGC, hertz, seconds). More...
 
UnifiedAutomation.UaBase.Range EURange [get, set]
 Gets or sets the EURange More...
 
UnifiedAutomation.UaBase.Range InstrumentRange [get, set]
 Defines the value range that can be returned by the instrument. More...
 
- Properties inherited from UnifiedAutomation.UaServer.DataItemModel
string Definition [get, set]
 A vendor-specific, human readable string that specifies how the value of this DataItem is calculated. More...
 
double ValuePrecision [get, set]
 Specifies the maximum precision that the server can maintain for the item based on restrictions in the target environment. More...
 
- Properties inherited from UnifiedAutomation.UaServer.BaseVariableModel
object Value [get, set]
 Gets or sets the value. More...
 
- Properties inherited from UnifiedAutomation.UaServer.ModelControllerBase
ModelHandle ModelHandle [get, set]
 Gets or sets the metadata handle. More...
 
object UserData [get, set]
 Gets or sets the user data. More...
 

Detailed Description

Constructor & Destructor Documentation

UnifiedAutomation.UaServer.BaseAnalogModel.BaseAnalogModel ( )

Initializes a new instance of the BaseAnalogModel class.

UnifiedAutomation.UaServer.BaseAnalogModel.BaseAnalogModel ( BaseAnalogModel  template)

Initializes a new instance of the BaseAnalogModel class.

Parameters
templateThe template.

Property Documentation

EUInformation UnifiedAutomation.UaServer.BaseAnalogModel.EngineeringUnits
getset

Specifies the units for the AnalogItem value (e.g., DEGC, hertz, seconds).

Understanding the units of a measurement value is essential for a uniform system. In an open system in particular where servers from different cultures might be used, it is essential to know what the units of measurement are. Based on such knowledge, values can be converted if necessary before being used. Therefore, although defined as optional, support of the EngineeringUnits Property is strongly advised.

To facilitate interoperability, OPC UA specifies how to apply the widely accepted “Codes for Units of Measurement (Recommendation No. 20)” published by the “United Nations Centre for Trade Facilitation and Electronic Business” (see UN/CEFACT). It uses and is based on the International System of Units (SI Units) but in addition provides a fixed code that can be used for automated evaluation. This recommendation has been accepted by many industries on a global basis.

The class UaEUInformation provides helper functions to create the unit information from a unitId provided as enumeration. The methods are UaEUInformation::fromUnitId and UaEUInformation::setEUInformation.

UnifiedAutomation.UaBase.Range UnifiedAutomation.UaServer.BaseAnalogModel.EURange
getset

Gets or sets the EURange

UnifiedAutomation.UaBase.Range UnifiedAutomation.UaServer.BaseAnalogModel.InstrumentRange
getset

Defines the value range that can be returned by the instrument.

Although defined as optional, it is strongly recommended for Servers to support this Property. Without an InstrumentRange being provided, Clients will commonly assume the full range according to the DataType.