ANSI C Based OPC UA Client/Server SDK
1.8.2.394
|
Asynchronous call to modify a Subscription. More...
#include <opcua_types.h>
Data Fields | |
OpcUa_UInt32 | SubscriptionId |
The Server-assigned identifier for the Subscription. | |
OpcUa_Double | RequestedPublishingInterval |
This interval defines the cyclic rate that the Subscription is being requested to return Notifications to the Client. More... | |
OpcUa_UInt32 | RequestedLifetimeCount |
The requested lifetime count. More... | |
OpcUa_UInt32 | RequestedMaxKeepAliveCount |
Requested maximum keep-alive count. More... | |
OpcUa_UInt32 | MaxNotificationsPerPublish |
The maximum number of notifications that the Client wishes to receive in a single Publish response. More... | |
OpcUa_Byte | Priority |
Indicates the relative priority of the Subscription. More... | |
Asynchronous call to modify a Subscription.
Illegal request values for parameters that can be revised do not generate errors. Instead the server will choose default values and indicate them in the corresponding revised parameter.
Changes to the Subscription settings shall be applied immediately by the Server. They take effect as soon as practical but not later than twice the new OpcUa_ModifySubscriptionResponse::RevisedPublishingInterval.